  • What does F mean on the boiler? - FindAnyAnswer.com

    If your Glow-Worm boiler is displaying the F1 fault code, it means there has been an issue with the ignition sequence. And, when a fault code is shown on the display panel, it's likely that your boiler will lock out. It won't work again until the problem has …Get Price

  • Glow Worm Boilers: Problems and How To Fix Them | Heating Wise

    Dec 21, 2021 · When the F28 fault code appears, the boiler is usually disabled, making it secure. The fault code indicates that there may be a leak in the system. Don't try to reset the boiler in this situation since there could be a leak. The F28 fault code will cause the pressure relief valve to open, releasing gas into your plenum.Get Price

  • Fault Finding Codes - Glow-worm - Replacement Boiler

    Codes Description; F1: Ignition fault : F3: Fan unable to reach ignition speed : F4: Ignition fault : F5: Overheat Fault : F6: Central heating flow thermistor : F9: Water pressure sensor fault, blocked flow filter or pump fault : F10: Central return flow thermistor : F11: Main board connection fault : F13: PCB memory or sensing fault : F14: Gas Get Price

  • Ask Glow-worm

    Fault Description. Possible Causes. Fault Code F1. Ignition Failure (Boiler Has Tried To Ignite 5 Times And Failed) Insufficient Inlet Working Gas Pressure At The Appliance. Flue Problem. Condensate Blockage. Blockage Within The Combustion Side Of The Main Heat Exchanger. Burner Problem.Get Price

  • F1 error - Boiler needing repair or just bothersome

    Feb 04, 2009 · We have a glowworm boiler model 30ci, and every winter on the few coldest days it doesn't start automatically. It gives an F1 error, and after a couple of tries lights fine and works perfectly until another particularly cold day. This seemed to happen on about 5 days each winter over the last few years.Get Price

  • Glow-Worm SXI Boiler Range Error Codes

    Boiler Fault Finder Ltd Pine Villa Wolborough Close, Newton Abbot Devon TQ12 1HR . Email: [email protected] Web: boilerfaultfinder.com. Boiler Fault Finder Ltd. Registered in England Number: 8610232 Google+Get Price

  • F1 fault code on glowworm flexicom 30cx? = Answered | Mend

    F1 fault code on glowworm flexicom 30cx? I have the fault code F1 flashing on y boiler, have checked the overflow pipe to no avail, can anyone help please. Have no hot water nor heating thanx. Kim Poppa October 2010. Heating, Home Heating Systems F1 Boiler Checked.Get Price

  • Have a Glowworm Ultracom 30cxi, getting fault codes F1 and

    Have a Glowworm Ultracom 30cxi, getting fault codes F1 and F4 (ignition fault) there is a good spark and the gas lights - Answered by a verified Plumber. Have a 3 year old Glow Worm Ultracom boiler,radiators with individual stats on them and a programmable timer in the kitchen.Get Price

  • British Gas - 330 - FREE BOILER MANUALS

    Fault Finding 12 31 Replacement of Parts 13 35 Manual Handling 14 40 Spare Parts 15 41 Declaration of conformity 16 43. 3 0020008877-04 of the boiler. It is normal and not a fault indication. Cleaning The boiler casing can be cleaned using a mild liquid detergent with a damp cloth, then a dry cloth to polish. Get Price

  • Glow-worm Ultracom hxi Boiler Faults, Problems and Fault

    Nov 01, 2020 · Glo w-worm Ultracom hxi boiler showing F1 fault code This fault also occurs with the British Gas BG 330 boiler which is based on the Ultracom hxi. The boiler was showing an F1 fault code. After re-setting, it attempted to go through the ignition sequence but consistently failed. After 5 attempts it locked out, showing the F1 fault code again.Get Price

  • Glow Worm Boilers: Problems and How To Fix Them | Heating Wise

    Dec 21, 2021 · When the F28 fault code appears, the boiler is usually disabled, making it secure. The fault code indicates that there may be a leak in the system. Don't try to reset the boiler in this situation since there could be a leak. The F28 fault code will cause the pressure relief valve to open, releasing gas into your plenum.Get Price

  • Glow-Worm Boiler Error Codes / Fault Codes | WarmZilla

    Feb 15, 2020 · Hi, this quick video shows you how I fixed the F1 fault code that appeared on my boiler when I arrived back from holiday last summer.Get Price

  • Glow-Worn Boiler F1 Fault Code - Plumbing | Heating | Gas

    Glow-Worn Boiler F1 Fault Code - EPHG LimitedGet Price

  • 2021 Glow Worm Boiler Error & Fault Codes Explained

    Fault Code Possible Cause; F1: Ignition fault: F2: Fan/APS: F3: Air fault: F4: Ignition fault: F5: Overheat Fault: F6: Central heating flow thermistor: F7: Domestic Get Price

  • Fault Finding Codes - Glow-worm - Replacement Boiler

    F12. Connection fault between main pcb and display pcb. F13. Main pcb connection fault. F14. Central heating flow temperature > 95 degrees. F16. Flame detection fault. F17.Get Price

  • Glow-worm Boiler Problems, Repair Advice & How to Fix

    Glow-worm boilers come with 2-7 years of warranty as standard but some models are eligible for up to 15 years of warranty through Glow-worm's club energy installers. Find out more with our guide to Glow-worm warranties. Keeping the warranty valid means arranging for an annual service of your Glow-worm boiler that will also ensure the safe and Get Price

  • F1 Boiler Fault Meaning - New Water Leak? - WaterLeak.co.uk

    Does F1 Combi Boiler Fault Mean I Have a Leak? Well the simple answer is possibly, if you have a water leak, it will obviously cause water to leak out of the central heating system thus causing water to drop. If you top up the pressure on the system, as per the manufacturers instructions, but still get a pressure drop that increases the chances Get Price

  • F1 fault on 38cxi glow worm - fault seems to appear

    Jun 17, 2012 · F1 fault on 38cxi glow worm - fault seems to appear overnight - power down and reset and all seems well for next 24 - Answered by a verified Plumber Hi There, we have Glow Worm Flexicom 15 Hx heat only boiler, the fault code F22 keeps shoing, there is no issue with the pressure and no issue with the heat ex. The system is gravity fed.Get Price

  • glow worm 30cxi boiler f1 fault? = Answered | Mend Heating

    Mr & Mrs Smith. October 2012. the f1 fault code is a code that appears for many different faults if appears and boiler will not run then is a pcb change if only happens when dhw run then blocked heat exchanger or over heat stat thimister if on ch then pump or blocked heat exchanger very hard to fault find what ever it is will be expensive Get Price

  • Fault Finding Codes - Glow-worm - Replacement Boiler

    Codes Description; F1: Ignition fault: F3: Fan unable to reach ignition speed : F4: Ignition fault: F5: Overheat Fault: F6: Central heating flow thermistor : F9: Low water pressure Sensor : F10: Central return flow thermistor : F11: Flow and or return thermistor fault : F13: PCB memory or sensing fault : F14: Gas valve control defective : F15 Get Price

  • Fault Codes Request – MyBoiler.com

    Fault Codes Request. Welcome to the fault-codes section of this site. The following table or page contains the information required to help repair and diagnose the fault codes being shown on the boiler display. You may be guided through the fault finding sequence or steps, for rectifying your boiler with this fault code.Get Price

  • 2021 Glow Worm Boiler Error & Fault Codes Explained

    Fault Code Possible Cause; F1: Ignition fault: F2: Fan/APS: F3: Air fault: F4: Ignition fault: F5: Overheat Fault: F6: Central heating flow thermistor: F7: Domestic Get Price

  • The GlowWorm Boiler Fault Code F1 Error Common Q A EPHG

    Other reason for a F1 Fault on a Glow Worm boiler. When getting a gas engineer out, the first thing you may want to get is a list of problem as some gas engineer just don't have a clue and will seek advice from the fault finding books. Other problems could be; the gas may need Purging, the Printed Circuit Board (PCB) has possibly gone Get Price

  • Glow Worm 18hxi F1 fault | DIYnot Forums

    Jan 23, 2010 · Hi, I've just moved into a new house with a Glow worm 18hxi boiler. I keep getting an F1 fault and it turns itself off. I have little info on the boiler and the estate agent (its a rented property) says I need to check the pressure of the system before they will send someone out to help, and then not help me with how I do that!Get Price

  • Brtish Gas 330 (glow worm) boiler faults - Central Heating

    Oct 31, 2010 · Seems odd the faults have started since changing a rad, the overheat fault could be from air in the system so make sure it is bled properly. The gurgling you hear above the boiler is probably air stuck in the pipes there. I would imagine the failing to light fault is because of the overheat situation. And as a general comment, Glow Worm are crap.Get Price

  • Glow Worm Boiler Fault Code | AllBoiler

    Glow Worm Boiler Fault Code Glow Worm boilers vary by simple identification of problems with the help of Glow Worm boiler fault codes. Below are 2 tables, thanks to which you can not only determine the cause of the problem, but in some cases you could fix the problem yourself.Get Price

  • Glow-worm Fault Codes - FREE BOILER MANUALS

    Glow Worm fault codes. Boiler Model Fault Code Cause of Problem; Betacom: Red LED on: Lockout – low water pressure (increase pressure to 1.5bar) and reset boilerGet Price

  • Glow Worm 18hxi F1 fault | DIYnot Forums

    Jan 23, 2010 · Hi, I've just moved into a new house with a Glow worm 18hxi boiler. I keep getting an F1 fault and it turns itself off. I have little info on the boiler and the estate agent (its a rented property) says I need to check the pressure of the system before they will send someone out to help, and then not help me with how I do that!Get Price

  • Glow-Worn Boiler F1 Fault Code - Plumbing | Heating | Gas

    Ideal Boiler F1 Fault Code Explained [And How To Fix It]Get Price

  • Fault Finding Codes | Boilers | Glow-worm

    Dec 07, 2021 · What Does the F1 Boiler Fault Code Mean? The Ideal boiler F1 fault code means there is a lack of pressure in your heating system, most likely because there simply isn't enough water. If you see an F1 on a boiler, you may also see lights flashing on the front of your appliance. The boiler won't work again until you raise the pressure and reset it.Get Price

  • Glow worm 30CXI combination boiler showing fault code F1

    Thank you for this post - i t helped massively. We initially had a fault 22 code and the boiler was making a loud rumbling noise. I remembered that a friend had a similar problem a few weeks ago and promptly emptied a couple of kettles onto the external flue which momentarily rectified the problem but then it restarted with the F1 code I disconnected the pipe underneath the boiler …Get Price

  • Glow worm flexicom 24 hx fault | DIYnot Forums

    Sep 03, 2019 · I have come home to find the boiler in fault mode flashing F1. Other than some initial F22 fault codes before outside pipe was lagged it has always run but now have this fault. Pressed the reset and it has fired with a bit of a whoosh when the flame lit.Get Price

  • Glow-worm Ultracom hxi Boiler Faults, Problems and Fault

    Nov 01, 2020 · The boiler was showing an F1 fault code. After re-setting, it attempted to go through the ignition sequence but consistently failed. After 5 attempts it locked out, showing the F1 fault code again. The Ultracom hxi Installation and Servicing Instructions are good on this fault. They list a string of possibilitiesGet Price

  • Glow-Worm Ultracom CX Boiler Range Error Codes

    Boiler Fault Finder Ltd Pine Villa Wolborough Close, Newton Abbot Devon TQ12 1HR . Email: [email protected] Web: boilerfaultfinder.com. Boiler Fault Finder Ltd. Registered in England Number: 8610232Get Price

  • Fixing a F1 Fault Code on a Glow-Worm Flexicom 18hx …

    Glow-Worn Boiler F1 Fault Code - EPHG LimitedGet Price

  • Gas Central Heating Blog: Jaguar Combi Boiler F1 and F3 Error

    Jun 04, 2012 · I realised that the F1 code was due to the overheat thermostat cutting the boiler out and not allowing the boiler to light. I reset the overheat thermostat and the boiler was able to light again. Running the boiler for the hot water, the boiler got up to temperature quickly and cut out before the hot water was hot at the tap.Get Price

  • British Gas 330 F1 fault | DIYnot Forums

    Sep 03, 2019 · Country: Hi, have an approx 2 year old "330" boiler fitted by British Gas, gas fired. All fine until about 6 months ago it begins shutting down with an F1 code. If you switch the On/Off selector it restarts ok. I'm not sure when it does it, either when on or off, because you just notice the house got cold and then find the boiler is off.Get Price

  • How to FIX Fault Code F1 on a Glow Worm Flexicom 18hx …

    Glow-Worn Boiler F1 Fault Code - EPHG LimitedGet Price

  • Glow Worm Boiler Fault F1 or F4 - YouTube

    Mar 02, 2018 · How to fix, Glow Worm Boiler Fault F1 & F4My boiler location on 1st floor very hard to defrost the out pipe. Outside Temperature -15c. Condensation Pipe blocGet Price

  • F1 Boiler Fault Meaning - New Water Leak? - WaterLeak.co.uk

    Does F1 Combi Boiler Fault Mean I Have a Leak? Well the simple answer is possibly, if you have a water leak, it will obviously cause water to leak out of the central heating system thus causing water to drop. If you top up the pressure on the system, as per the manufacturers instructions, but still get a pressure drop that increases the chances Get Price

  • Ideal Boiler F1 Fault Code Explained [And How To Fix It]

    Sep 17, 2020 · In this video I show you how I fixed the fault code F1 from a Glow-worm gas boiler by resetting it. The F1 fault code means there has been a problem with theGet Price

  • I am getting an F1 Fault on my Glow Worm boiler, what …

    If your Glow-Worm boiler is displaying the F1 fault code, it means there has been an issue with the ignition sequence. There are various ignition faults that can stop your boiler from working. Fault codes on Glow-Worm boilers will help your engineer to figure out what the problem is, quicker than if they had to fault-find from scratch.Get Price

  • Fault Finding Codes - Glow-worm - Replacement Boiler

    Codes Description; F1: Ignition fault: F3: Fan unable to reach ignition speed : F4: Ignition fault: F5: Overheat Fault: F6: Central heating flow thermistor : F7: Domestic hot water thermistor : F9: Water pressure sensor fault, blocked flow filter or pump fault : F10: Central return flow thermistor : F11: Flow and or return thermistor fault Get Price

  • Glow Worm 18hxi F1 fault | DIYnot Forums

    Jul 14, 2021 · Glow-worm Error Codes F1, F4, F28 or F29. If you are seeing the error codes F1, F4 F28, or F29 on your boiler there's an issue with your condensate pipe. This error appears when your pipe is frozen, which can happen during the cold months as it runs outdoors.Get Price

  • Ferroli boiler error codes | AllBoiler

    F30 - CH flow sensor fault. • Sensor damaged or short circuited. • Check the wiring or change the sensor. F31 - CH flow sensor fault. • Sensor damaged or wiring broken. F34 - Supply voltage under 190V. or over 250V. • Electric mains fault. • Check the electrical system. F35 - …Get Price

  • Boiler Fault Codes - Mr Engineers

    May 03, 2020 · Mr Engineers Our team are certified & licensed Gas Safe Engineers ready to provide you with all types of landlord safety certificates in London and the M25 area for domestic purposes.. At Mr Engineers, we treat each customer with utmost respect that they really deserve. Our dedicated staff provides great customer service to ensure that you have a memorable …Get Price

  • Glow Worm Fault Codes – MyBoiler.com

    Glow Worm Fault Codes. Welcome to the fault-codes section of this site. The following table or page contains the information required to help repair and diagnose the fault codes being shown on the boiler display. You may be guided through the fault finding sequence or steps, for rectifying your boiler with this fault code.Get Price